High-Resolution Mass Spectrometry Molecular Weight Identification

The mass spectrometry widely used for protein identification currently includes two types: one is MALDI-TOF, which directly measures molecular weight; the other is LC-MS, which performs high-resolution mass spectrometry on multiple charged signals obtained by electrospray, followed by deconvolution analysis of the signals to obtain precise molecular weight values. Each method has its advantages and applicable fields. Biotech Paker BioTech is equipped with both mass spectrometry systems, which can be used for molecular weight determination of various protein samples, meeting various protein molecular weight analysis needs, including peptide fingerprinting and protein identification.

百泰派克生物科技累计多年质谱经验推出:抗体类蛋白质药物,还原后抗体类样品的不同亚基,小分子量(<10KDa)蛋白质样品的精确分子量测定一站式服务

ESI ion spray molecular weight determination

 

Case Analysis:

1 Precise molecular weight determination of a protein drug with a molecular weight greater than 10KDa
Biotech Paker collects the original signals directly using the Q Exactive mass spectrometer after online reverse-phase chromatography separation. Then, ProMass for XcaliburTM is used to perform deconvolution calculation on the original data to obtain the precise molecular weight of the sample.

A UV detector is connected during the reverse-phase chromatography separation process before entering the mass spectrometer (as shown in the figure below), which evaluates the sample's purity while achieving sample separation; the chromatography separation process also reduces the requirement for sample purity in precise molecular weight detection.

进入质谱之前的反相色谱分离过程中连接了紫外检测器

 

High-resolution mass spectrometry molecular weight - Biotech Paker BioTech


When analyzing the original mass spectrometry data using software, the molecular weight of the main and minor components in the sample can be selected and analyzed according to TIC (Total Ion Chromatogram).

利用软件对质谱原始数据进行分析时,可以根据TIC(总离子流图)分别对样品中的主要成分和次要成分的分子量进行选择和分析


For example, to analyze the molecular weight of the main component marked in the red box in the figure above, we only need to find the mass spectrometry original data obtained at that moment (as shown in the figure below).

质谱原始数据

 

Mass spectrometry original data - Biotech Paker BioTech


Then, the above original data is deconvoluted to obtain the precise molecular weight of the main component in the protein sample (as shown in the figure below).

对原始数据进行去卷积处理,得到该蛋白样品中主要成分的精确分子质量

 

Precise molecular weight


2 Precise molecular weight determination of a peptide drug with a molecular weight less than 10KDa
Biotech Paker BioTech collects the original signals directly using the Q Exactive mass spectrometer after online reverse-phase chromatography separation and then directly calculates the original data using the classical method of molecular weight calculation to obtain the precise molecular weight of the sample.
A UV detector is connected during the reverse-phase chromatography separation process before entering the mass spectrometer (as shown in the figure below), which evaluates the sample's purity while achieving sample separation; the chromatography separation process also reduces the requirement for sample purity in peptide precise molecular weight detection.

进入质谱之前的反相色谱分离过程中连接了紫外检测器


In the process of calculating precise molecular weight of the peptide, we only need to find the mass spectrometry original data at the elution time point of the peptide (as shown in the figure below)

20221219-6109-高分辨质谱分子量7.png


According to the classical method of molecular weight calculation, the molecular weight of molecules with two or more charges is calculated to obtain the precise molecular weight of the peptide sample.

20221219-6985-高分辨质谱分子量8.png


At the same time, we will provide you with the original mass spectrometry data of high-abundance charged ions for reference (as shown in the figure below).

20221219-7493-高分辨质谱分子量9.png

Comparison of the advantages and disadvantages of MALDI and ESI:

20221219-8403-高分辨质谱分子量10.png

A UV detector is connected during the reverse-phase chromatography separation process before entering the mass spectrometer

In the technical report, Biotech Paker will provide you with a detailed bilingual (Chinese and English) technical report, including:

1. Experimental steps (Chinese and English)
2. Relevant mass spectrometry parameters (Chinese and English)
3. Mass spectrometry images
4. Original data
5. Protein/peptide molecular weight information

One-stop service for high-resolution mass spectrometry molecular weight determination

You just need to place an order - send samples
Biotech Paker's one-stop service completes: sample processing - on-machine analysis - data analysis - project report

Related services

Molecular weight determination
MALDI TOF molecular weight analysis
Protein molecular weight determination
Molecular weight determination of protein complexes, protein and small molecule complexes

 

Submit Inquiry
Name *
Email Address *
Phone Number
Inquiry Project
Project Description*

 

How to order?